STVI 2050
Measuring instrument
Aplicaciones
The STVI 2050 is used for measuring and adjusting the fl
ow and pressure in hot, cold and tap water systems.
After the measurements have been taken and adjustments
made the data is saved on the hand terminal and can then
be transferred to a PC, for later documentation of the
project in Excel fi les.
Description
The STVI 2050 consists of a sensor with indicator
needles for measuring alternating pressure and fl ow,
plus a hand terminal for managing, storing and
displaying measurements. These two units communicate
wirelessly using Bluetooth technology. The sensor is
connected to the object’s measuring socket and
measurements are taken according to the instructions.
The gauge has characteristics for the most common
regulator valves on the market, which also allows
measurement of manufacturers other than MMA Balance. The
gauge also contains complete software for gathering,
storing and documenting values onto the hand terminal
and PC.
Tehnical data
Alternating pressure
up to 200 kPa
Max static pressure
1000 kPa
Accuracy, alternating pressure
at < 10 kPa ± 0.1 kPa
at > 10 kPa ± 1% of value displayed
Liquefaction, alternating pressure
at < 10 kPa ± 0.01 kPa
at > 10 kPa ± 0.1 kPa
Accuracy, flow
same as for alternating pressure + discrepancy of the
valve
Liquefaction, flow
0.001 l/s
Temperature
mean -10°C - +100°C
stored -20°C - +60°C
Humidity, non-condensing
max 90% RH
Electrical supply
4 rechargeable NiMH AA HR6 batteries, 2400 mAh
System requirements, hand terminal
Microsoft®Windows Mobile ™2003
Bluetooth®wireless technology
System requirements, PC
Microsoft Windows®2000/XP
|
|
 |
| |
|
|
| |
|
|
|